DSpace
 

Rubicon Research Repository >
Rubicon Foundation Archive >
Technical Reports and Workshops >
Naval Experimental Diving Unit (NEDU) >

Please use this identifier to cite or link to this item: http://archive.rubicon-foundation.org/3529

Title: Underwater Purging Procedures for the Draeger LAR V UBA (Underwater Breathing Apparatus).
Authors: Butler Jr, FK
Keywords: DIVER EQUIPMENT
BREATHING APPARATUS
OXYGEN
OXYGEN EQUIPMENT
PROTECTIVE MASK FACEPIECES
PARTIAL PRESSURE
UNDERWATER EQUIPMENT
CLOSED CYCLE SYSTEMS
BREATHING MASKS
PURGING
Issue Date: 1986
Abstract: The U.S. Navy has identified a need to switch to the Draeger LAR V closed-circuit oxygen Underwater Breathing Apparatus from open-circuit air while underwater. The revised purge procedure described in NEDU Report 5-84 and subsequently approved for fleet use was tested only at 1 ATA. This study was carried out to develop a purge procedure suitable for use underwater. Three different purge procedures were tested. The incluence of diver position in the water during the procedure and the type of open circuit air facemask regulator configuration used prior to switching to the LAR V were also examined.
Description: Citation Status: Active; Citation Classification: Unclassified; Title Classification: Unclassified; Report Classification: Unclassified; Identifier Classification: Unclassified; Abstract Classification: Unclassified; Distribution Limitation(s): 01 - APPROVED FOR PUBLIC RELEASE; Information provided by the Department of Defense and the Defense Technical Information Center (http://www.dtic.mil/) is considered public information and may be distributed or copied unless otherwise specified. Use of appropriate byline/photo/image credits is requested.
Gov't Doc # : ADA170822
NEDU-6-86
URI: http://archive.rubicon-foundation.org/3529
Appears in Collections:Naval Experimental Diving Unit (NEDU)

Files in This Item:

File SizeFormat
NEDU_1986_06.pdf3310KbAdobe PDFView/Open

All items in DSpace are protected by copyright, with all rights reserved.

 