Rubicon Research Repository >
Rubicon Foundation Archive >
Technical Reports and Workshops >
Navy Experimental Diving Unit (NEDU) >
Please use this identifier to cite or link to this item:
http://archive.rubicon-foundation.org/7406
|
| Title: | Oxygen Consumption Rate of Operational Underwater Swimmers. |
| Authors: | Knafelc, ME |
| Keywords: | DIVERS BREATHING APPARATUS DIVER EQUIPMENT OXYGEN CONSUMPTION SWIMMERS BOTTLES canisters CARBON DIOXIDE OXYGEN pressure TRAINING Time Factors UNCONVENTIONAL WARFARE UNDERWATER EQUIPMENT UNDERWATER closed circuit rebreather human |
| Issue Date: | 1989 |
| Publisher: | NAVY EXPERIMENTAL DIVING UNIT PANAMA CITY FLA |
| Citation: | ADA205331 |
| Abstract: | Prior to evaluating an underwater breathing apparatus (UBA), diver performance must be determined. Previous studies determining the oxygen consumption of swimming and resting divers were done in the laboratory and were limited in scope. Criticisms of those studies suggested that they may not have accurately simulated the underwater work expected of an operational diver. This study measured the oxygen consumption (VO2) sustained by experienced Special Warfare (SPECWAR) operators participating in training exercises. By using a closed-circuit oxygen underwater breathing apparatus, the decrease in the oxygen bottle pressure reflected the amount of oxygen consumed by the diver. Combat swimmers, swimming at their own pace, had a mean V.O2 of 1.5 +/- 0.2 (SD) liters per minute (lpm), (n=8). Resting divers mean V.O2 was 0.64 +/- 0.09 (SD) lpm (n=12). These values are comparable to the results of the previous studies. Guidelines reflecting underwater oxygen consumption and estimating carbon dioxide production for calculating carbon dioxide canister duration should be based on the results of these studies. |
| Description: | Citation Status: Active; Citation Classification: Unclassified; Title Classification: Unclassified; Report Classification: Unclassified; Identifier Classification: Unclassified; Abstract Classification: Unclassified; Distribution Limitation(s): 01 - APPROVED FOR PUBLIC RELEASE; Information provided by the Department of Defense and the Defense Technical Information Center (http://www.dtic.mil/) is considered public information and may be distributed or copied unless otherwise specified. Use of appropriate byline/photo/image credits is requested. |
| Gov't Doc # : | ADA205331 NEDU-1-89 |
| URI: | http://archive.rubicon-foundation.org/7406 |
| Appears in Collections: | Navy Experimental Diving Unit (NEDU)
|
Files in This Item:
| File |
Description |
Size | Format |
| NEDU_1989_1.pdf | | 721Kb | Adobe PDF | View/Open |
|
All items in DSpace are protected by copyright, with all rights reserved.
|