Manned Evaluation of MK-15 Closed-Circuit UBA Cannister Duration at 13.4 C and 2 C.

Rubicon Research Repository/Manakin Repository

Manned Evaluation of MK-15 Closed-Circuit UBA Cannister Duration at 13.4 C and 2 C.

Show simple item record


dc.contributor NAVY EXPERIMENTAL DIVING UNIT PANAMA CITY FL en_US
dc.contributor.author Jaggears, FR en_US
dc.contributor.author Thalmann, ED en_US
dc.date.accessioned 2006-08-30T03:12:05Z
dc.date.available 2006-08-30T03:12:05Z
dc.date.issued 1983 en_US
dc.identifier.govdoc ADA131802 en_US
dc.identifier.govdoc NEDU-6-83 en_US
dc.identifier.uri http://archive.rubicon-foundation.org/3293
dc.description Citation Status: Active; Citation Classification: Unclassified; Title Classification: Unclassified; Report Classification: Unclassified; Identifier Classification: None; Abstract Classification: Unclassified; Distribution Limitation(s): 01 - APPROVED FOR PUBLIC RELEASE; Information provided by the Department of Defense and the Defense Technical Information Center (http://www.dtic.mil/) is considered public information and may be distributed or copied unless otherwise specified. Use of appropriate byline/photo/image credits is requested. en_US
dc.description.abstract (U) The carbon dioxide absorbent cannister duration of the MK-15 closed circuit Underwater Breathing Apparatus (UBA) was evaluated during moderate exercise in cold water of 13.4 C and 2 C at 65 FSW. The Passive Diver Thermal Protection System (PDTPS) was worn during the study to evaluate the thermal protection it provides at 65 FSW. Results demonstrate that the safe operational limit of the MK-15 UBA is 117.5 minutes at either 13.4 C or 2 C and the PDTPS provides adequate thermal protection to the diver operating in these temperatures at 65 FSW. en_US
dc.format.extent 2622149 bytes
dc.format.mimetype application/pdf
dc.language.iso en_US
dc.rights Citation Status: Active; Citation Classification: Unclassified; Title Classification: Unclassified; Report Classification: Unclassified; Identifier Classification: None; Abstract Classification: Unclassified; Distribution Limitation(s): 01 - APPROVED FOR PUBLIC RELEASE; Information provided by the Department of Defense and the Defense Technical Information Center (http://www.dtic.mil/) is considered public information and may be distributed or copied unless otherwise specified. Use of appropriate byline/photo/image credits is requested. en_US
dc.subject Scuba apparatus en_US
dc.subject Canisters en_US
dc.subject Carbon dioxide en_US
dc.subject Absorption en_US
dc.subject Safety en_US
dc.subject Performance(Engineering) en_US
dc.subject Underwater en_US
dc.subject Thermal properties en_US
dc.subject Protection en_US
dc.subject Low temperature en_US
dc.title Manned Evaluation of MK-15 Closed-Circuit UBA Cannister Duration at 13.4 C and 2 C. en_US

Files in this item

Files Size Format View
NEDU_1983_06.pdf 2.500Mb PDF View/Open