Miscellaneous Considerations Regarding Closed Circuit Oxygen Scuba.

Rubicon Research Repository/Manakin Repository

Miscellaneous Considerations Regarding Closed Circuit Oxygen Scuba.

Show full item record


Title: Miscellaneous Considerations Regarding Closed Circuit Oxygen Scuba.
Author: Leyden, CJ; Searle, WF, Jr; Zamperini, AL
Abstract: The status of several closed circuit oxygen scuba is reviewed and recommendations for future developments are made. The German Drager and the USN Mark 3 are discussed in some detail and the USN Mark 4 is briefly described. Further improvements of the Mark 3 are enumerated and continued development is recommended, concurrently with development of the wholly new Mark 4 unit. A brief review of early closed circuit oxygen scuba is included along with an anotated bibliography of previous reports pertinent to this type breathing apparatus. (Author)
Description: Citation Status: Active; Citation Classification: Unclassified; Title Classification: Unclassified; Report Classification: Unclassified; Identifier Classification: Unclassified; Abstract Classification: Unclassified; Distribution Limitation(s): 01 - APPROVED FOR PUBLIC RELEASE; Information provided by the Department of Defense and the Defense Technical Information Center (http://www.dtic.mil/) is considered public information and may be distributed or copied unless otherwise specified. Use of appropriate byline/photo/image credits is requested.
URI: http://archive.rubicon-foundation.org/3335
Date: 1959

Files in this item

Files Size Format View
NEDU_1959_25.pdf 7.098Mb PDF View/Open

This item appears in the following Collection(s)

Show full item record

Browse

My Account