Evaluation of the Mark 11 Mod 0 UBA in Cold Water.

Show full item record


Title: Evaluation of the Mark 11 Mod 0 UBA in Cold Water.
Author: O'Bryan, RK; Clinton, RL; Vendetto, RA
Abstract: The MK 11 Mod 0 UBA was evaluated for its ability to efficiently absorb carbon dioxide during prolonged moderate work in cold water. In addition, thermal protection of the absorbent bed and the degree of inspired gas warming were analyzed. The results show that near the surface the apparatus can efficiently absorb CO2 for prolonged periods in cold water, and that the absorbent bed is thermally protected. However, there was a virtual absence of inspired gas warming which may be a limiting factor for a diver at depth. (Author)
Description: Citation Status: Active; Citation Classification: Unclassified; Title Classification: Unclassified; Report Classification: Unclassified; Identifier Classification: Unclassified; Abstract Classification: Unclassified; Distribution Limitation(s): 01 - APPROVED FOR PUBLIC RELEASE; Information provided by the Department of Defense and the Defense Technical Information Center (http://www.dtic.mil/) is considered public information and may be distributed or copied unless otherwise specified. Use of appropriate byline/photo/image credits is requested.
URI: http://archive.rubicon-foundation.org/3507
Date: 1978

Files in this item

Files Size Format View
NEDU_1978_10.pdf 1.887Mb PDF View/Open