Statistically Based CO2 Canister Duration Limits for Closed-Circuit Underwater Breathing Apparatus.

Rubicon Research Repository/Manakin Repository

Statistically Based CO2 Canister Duration Limits for Closed-Circuit Underwater Breathing Apparatus.

Show full item record


Title: Statistically Based CO2 Canister Duration Limits for Closed-Circuit Underwater Breathing Apparatus.
Author: Clarke, JR
Abstract: Elementary statistical methods tare used to predict canister durations as a function of gas temperature and CO2 production rate. The canister duration data is fit to a 3 term polynomial using TableCurve 2D or similar curve fitting software. The best fit curve and the standard error of the estimate are used to derive prediction limits of varying degrees of confidence. Examples are given of the use of prediction limits in biomedical and manufacturing applications. From the prediction limits we can defines series of canister duration curves with increasing duration being associated with an increasing risk of canister breakthrough.
Description: Citation Status: Active; Citation Classification: Unclassified; Title Classification: Unclassified; Report Classification: Unclassified; Identifier Classification: Unclassified; Abstract Classification: Unclassified; Distribution Limitation(s): 01 - APPROVED FOR PUBLIC RELEASE; Information provided by the Department of Defense and the Defense Technical Information Center (http://www.dtic.mil/) is considered public information and may be distributed or copied unless otherwise specified. Use of appropriate byline/photo/image credits is requested.
URI: http://archive.rubicon-foundation.org/3557
Date: 1999

Files in this item

Files Size Format View
ADA362566.pdf 1.775Mb PDF View/Open

This item appears in the following Collection(s)