Statistically Based CO2 Canister Duration Limits for Closed-Circuit Underwater Breathing Apparatus.

Rubicon Research Repository/Manakin Repository

Statistically Based CO2 Canister Duration Limits for Closed-Circuit Underwater Breathing Apparatus.

Show simple item record


dc.contributor NAVY EXPERIMENTAL DIVING UNIT PANAMA CITY FL en_US
dc.contributor.author Clarke, JR en_US
dc.date.accessioned 2006-09-03T20:35:37Z
dc.date.available 2006-09-03T20:35:37Z
dc.date.issued 1999 en_US
dc.identifier.govdoc ADA362566 en_US
dc.identifier.govdoc NERDU TR REPT. 2-99 en_US
dc.identifier.govdoc XB-NAVSEA en_US
dc.identifier.other UBA(UNDERWATER BREATHING APPARATUS) en_US
dc.identifier.uri http://archive.rubicon-foundation.org/3557
dc.description Citation Status: Active; Citation Classification: Unclassified; Title Classification: Unclassified; Report Classification: Unclassified; Identifier Classification: Unclassified; Abstract Classification: Unclassified; Distribution Limitation(s): 01 - APPROVED FOR PUBLIC RELEASE; Information provided by the Department of Defense and the Defense Technical Information Center (http://www.dtic.mil/) is considered public information and may be distributed or copied unless otherwise specified. Use of appropriate byline/photo/image credits is requested. en_US
dc.description.abstract Elementary statistical methods tare used to predict canister durations as a function of gas temperature and CO2 production rate. The canister duration data is fit to a 3 term polynomial using TableCurve 2D or similar curve fitting software. The best fit curve and the standard error of the estimate are used to derive prediction limits of varying degrees of confidence. Examples are given of the use of prediction limits in biomedical and manufacturing applications. From the prediction limits we can defines series of canister duration curves with increasing duration being associated with an increasing risk of canister breakthrough. en_US
dc.format.extent 1862203 bytes
dc.format.mimetype application/pdf
dc.language.iso en_US
dc.rights Citation Status: Active; Citation Classification: Unclassified; Title Classification: Unclassified; Report Classification: Unclassified; Identifier Classification: Unclassified; Abstract Classification: Unclassified; Distribution Limitation(s): 01 - APPROVED FOR PUBLIC RELEASE; Information provided by the Department of Defense and the Defense Technical Information Center (http://www.dtic.mil/) is considered public information and may be distributed or copied unless otherwise specified. Use of appropriate byline/photo/image credits is requested. en_US
dc.subject CANISTERS en_US
dc.subject DIVERS en_US
dc.subject BREATHING APPARATUS en_US
dc.subject UNDERWATER LIFE SUPPORT SYSTEMS en_US
dc.subject COMPUTER PROGRAMS en_US
dc.subject TEMPERATURE en_US
dc.subject MANUFACTURING en_US
dc.subject RISK en_US
dc.subject PREDICTIONS en_US
dc.subject GASES en_US
dc.subject ERRORS en_US
dc.subject POLYNOMIALS en_US
dc.subject STATISTICAL PROCESSES en_US
dc.subject BIOMEDICINE en_US
dc.subject CURVE FITTING en_US
dc.title Statistically Based CO2 Canister Duration Limits for Closed-Circuit Underwater Breathing Apparatus. en_US