Lot Variability of Sofnolime 408 Carbon Dioxide Absorbent When Tested in the Cold

Rubicon Research Repository/Manakin Repository

Lot Variability of Sofnolime 408 Carbon Dioxide Absorbent When Tested in the Cold

Show full item record


Title: Lot Variability of Sofnolime 408 Carbon Dioxide Absorbent When Tested in the Cold
Author: Clarke, JR; Thompson, LD; Godgrey Jr, RJ
Abstract: NEDU performed quality assurance tests on 18 lots of Sofnolime 408, a large grain sodalime made by Molecular Products. CO2 absorption activity using the standard NATO tubs test was performed at initial absorbent bed temperatures of approximately 32 deg F. Moisture analyses and sieve tests were also performed on each sample. Absorption test breakthrough in the chilled bed occurred at an average of 7 min, compared to the usual 40 min duration under ambient conditions. Absorption activity was negatively correlated with increasing moisture content, and positively correlated with an increasing percentage of absorbent retained on the #8 sieve.
Description: Citation Status: Active; Citation Classification: Unclassified; Title Classification: Unclassified; Report Classification: Unclassified; Identifier Classification: Unclassified; Abstract Classification: Unclassified; Distribution Limitation(s): 01 - APPROVED FOR PUBLIC RELEASE; Information provided by the Department of Defense and the Defense Technical Information Center (http://www.dtic.mil/) is considered public information and may be distributed or copied unless otherwise specified. Use of appropriate byline/photo/image credits is requested.
URI: http://archive.rubicon-foundation.org/3573
Date: 1998

Files in this item

Files Size Format View
ADA355578.pdf 891.7Kb PDF View/Open