Manned Evaluation of Field Change 985 to the MK-11 UBA CO2 Absorbent Canister.

Rubicon Research Repository/Manakin Repository

Manned Evaluation of Field Change 985 to the MK-11 UBA CO2 Absorbent Canister.

Show simple item record


dc.contributor.author Gray, CG
dc.contributor.author Thalmann, ED
dc.date.accessioned 2007-08-08T01:52:48Z
dc.date.available 2007-08-08T01:52:48Z
dc.date.issued 1981
dc.identifier.citation ADA103352 en
dc.identifier.govdoc ADA103352
dc.identifier.govdoc NEDU-4-81
dc.identifier.uri http://archive.rubicon-foundation.org/4845
dc.description Citation Status: Active; Citation Classification: Unclassified; Title Classification: Unclassified; Report Classification: Unclassified; Identifier Classification: Unclassified; Abstract Classification: Unclassified; Distribution Limitation(s): 01 - APPROVED FOR PUBLIC RELEASE; Information provided by the Department of Defense and the Defense Technical Information Center (http://www.dtic.mil/) is considered public information and may be distributed or copied unless otherwise specified. Use of appropriate byline/photo/image credits is requested. en
dc.description.abstract Field Change No. 985 to the MK-11 Semi-Closed Circuit mixed-gas UBA underwent manned evaluation at a depth of 650 FSW in 35 F water. FC 985 splits the hot water supply to the diver with part heating sheath-surrounded breathing bags and hoses and part being routed to a heat exchanger inside the CO2 absorbant canister. The results of 6 manned canister duration studies showed that the canister effluent CO2 was less than 1 mmHg after canister times ranging from 5 hrs 10 min to 6 hrs 2 min. This was a significant improvement over canister duration times of previous MK-11 configuration studies. A canister duration of 6 hours was assigned to the FC 985 canister. No significant differences in breathing resistance from the previous MK-11 configuration were noted. Inspired gas temperatures exceeded the minimum inspired temperature limit of 60.3 F at 650 FSW. en
dc.description.sponsorship US NAVY en
dc.format.extent 1790561 bytes
dc.format.mimetype application/pdf
dc.language.iso en_US en
dc.publisher NAVY EXPERIMENTAL DIVING UNIT PANAMA CITY FLA en
dc.subject DIVING en
dc.subject DIVER EQUIPMENT en
dc.subject BREATHING APPARATUS en
dc.subject ABSORPTION en
dc.subject SCRUBBERS en
dc.subject carbon dioxide en
dc.subject rebreather en
dc.subject CANISTERS en
dc.subject ABSORBERS(EQUIPMENT) en
dc.subject heating en
dc.subject CIRCULATION en
dc.subject DIVING SUITS en
dc.subject HOT WATER en
dc.subject BREATHING GASES en
dc.subject CLOSED CYCLE SYSTEMS en
dc.title Manned Evaluation of Field Change 985 to the MK-11 UBA CO2 Absorbent Canister. en
dc.type Technical Report en