| dc.contributor |
NAVAL SUBMARINE MEDICAL RESEARCH LAB GROTON CT |
en_US |
| dc.contributor.author |
Russotti, JS |
en_US |
| dc.contributor.author |
Greeb, RE |
en_US |
| dc.date.accessioned |
2010-04-20 |
|
| dc.date.available |
2010-04-20 |
|
| dc.date.issued |
1973 |
en_US |
| dc.identifier.govdoc |
AD0775682 |
en_US |
| dc.identifier.govdoc |
NSMRL-754 |
en_US |
| dc.identifier.govdoc |
XB-NSMRL |
en_US |
| dc.identifier.uri |
http://archive.rubicon-foundation.org/8783 |
|
| dc.description |
Citation Status: Active; Citation Classification: Unclassified; Title Classification: Unclassified; Report Classification: Unclassified; Identifier Classification: Unclassified; Abstract Classification: Unclassified; Distribution Limitation(s): 01 - APPROVED FOR PUBLIC RELEASE; Information provided by the Department of Defense and the Defense Technical Information Center (http://www.dtic.mil/) is considered public information and may be distributed or copied unless otherwise specified. Use of appropriate byline/photo/image credits is requested. |
en_US |
| dc.description.abstract |
Experienced sonar operators were exposed to conditions of simulated sonar watchstanding over a 129-min period. Successive measurements on the same non-alerted contact taken every 43 min during the detection period showed no significant change in initial detection. These results indicate that under conditions where the operator's vigilance is maintained by a not-unusual frequency of contact (operators were presented six contacts at random intervals during each 43-min period) no change in operator initial detection performance is encountered. |
en_US |
| dc.format.extent |
805574 bytes |
|
| dc.format.mimetype |
application/pdf |
|
| dc.language.iso |
en_US |
|
| dc.rights |
Citation Status: Active; Citation Classification: Unclassified; Title Classification: Unclassified; Report Classification: Unclassified; Identifier Classification: Unclassified; Abstract Classification: Unclassified; Distribution Limitation(s): 01 - APPROVED FOR PUBLIC RELEASE; Information provided by the Department of Defense and the Defense Technical Information Center (http://www.dtic.mil/) is considered public information and may be distributed or copied unless otherwise specified. Use of appropriate byline/photo/image credits is requested. |
en_US |
| dc.subject |
MAN MACHINE SYSTEMS |
en_US |
| dc.subject |
FATIGUE(PHYSIOLOGY) |
en_US |
| dc.subject |
SONAR PERSONNEL |
en_US |
| dc.subject |
PERFORMANCE(HUMAN) |
en_US |
| dc.subject |
TEST METHODS |
en_US |
| dc.subject |
HEARING |
en_US |
| dc.title |
Aural Detection Performance Over A 129 Minute Simulated Sonar Watch |
en_US |